The BALN-RUIO-24P is a wired and wireless 8Port remote I/O controller designed to manage devices over Ethernet.
The communication protocol is Modbus TCP/RTU, which can be used as a TCP through the protocol module, or as an RTU by setting the "Module Converter" function to "No".
Digital Input: Dry Contact and Wet Contact Support
Digital Output: 5A 250Vac and 5A 30Vdc controllable
Analog Input: It can be changed according to the conditions of the site when it is shipped
(Example: From 1 to 4, 0 to 5V input is supported)
5 to 8 supports 4 to 20 ms of current input)
Accuracy: 10 bits
Ethernet, RS485 and WiFi communication support
It supports Passive Switch Value (Dry Contact) and Active Level (Wet Contact). The acceptable range of Active Level is as follows.:
8 Channel Digital Output.
RUIO-24P is basically set to be 0-5V for 1-4 channels and 4-20mA for 5-8 channels. If you need to change, you can change the module to the channels below.:
1) Current signal input: 4~20mA
2) Voltage signal input: 0~5V
3) Voltage signal input: 0~10V
4) Resistance value 0-10k or other resistance type temperature and humidity sensors...
Each DO and DI point is attached with LEDs indicating whether it is used or not, making it easier to know whether it is operating or not.
Demo remote IO control over RS485 or TCP/IP can be executed. Through demonstrations, remote operation of IO and AI data collection can be collected.
A perfect rs modbus and 485 tcp control, you can explain.Developed more convenient features, or engineers.
This device has a built-in window virtual port & device management tool. You can find points and modify parameters with just one button.
Demo remote IO control over RS485 or TCP/IP can be executed. Through demonstrations, remote operation of IO and AI data collection can be collected.
Direct digital controller (DDC) that supports building management through automatic control of HVAC facilities.
Customized configurations can be made according to the size of the control target.
Multifunctional industrial controller capable of wired and wireless transmission by connecting Digital/Analog input, output, and LoRa network.
IR transmission/reception control (energy management)
INPUT : ① Temperature : NTC 10kΩ ② Humidity : 0-100% ③ Current Sensor, AD Value
OUTPUT : ① Dry Contact switch ②Voltage : 0-10V DC
③ Current : 4-20mA
Communication is smooth with repeater intestines. (noise blocking)
24V AC/ 24V DC power combined type (convenient power supply)
It has a separate 24/5V DC output, so it can be used in various ways
STAND-ALONE function built-in
The temperature sensor port is built in separately
On-site Input/Output Point test is possible